| Avtorstvo: |
Matej FISCHINGER // 1.01 Izvirni znanstveni članek Peter FAJFAR // 1.01 Izvirni znanstveni članek
|
| Leto: |
1987 |
| Citat: |
FISCHINGER, Matej, TOMAŽEVIČ, Miha, CAPUDER, Franc,
FAJFAR, Peter, LUTMAN, Marjana, SZILACYI, Janoš. Študija potresne varnosti
velikopanelnega sistema SCT. Gradb. vestn., 1987, letn. 36, št. 11/12,
str. 241-248, ilustr. |
| Povzetek: |
Prikazani so rezultati raziskovalno-razvojnega
projekta novega velikopanelnegasistema SCT. Najprej so opisani osnovni principi
projektiranja potresno-varnih velikopanelnih sistemov kot tudi montažnih
konstrukcij nasploh. Na osnovi eksperimentalnih rezultatov smo razvili
analitični model inga vgradili v program DRAIN-2D-2. Raziskava je pokazala, da
dobra konstrukcijska zasnova sistema omogoča skoraj monolitni odziv pri zmernih
potresih. Eksperimentalno ugotovljeni in analitično simulirani rušni mehanizem
(zdrsi vertikalnih stikov v povezavi z upogibno plastifikacijo sten) pa
zagotavlja duktilno obnašanje tudi v primeru najmočnejših potresov, ki
jihpričakujemo v Jugoslaviji
The results of the research project on the
development of a new large-panel system SCT are given. Basic principles of
seismic resistant design of large-panel systems, as well as prefabricated
structures in general, are described first. Based on exprimental results new
analytical models were developed and incorporated into the DRAIN-2D-2 program.
Due to the system's good structural concept the research indicates that the
response of SCT large-panel buildings to moderately strong earthquakes will be
nearly monolithic. The experimentally observed and analytically predicted
failure mechanism (slip along vertical joints associated with flexural yielding
of walls) will, however, guarantee ductile behaviour even in the case of the
strongest earthquakes expected in Yugoslavia [COBISS.SI-ID 399975]
|